%Header Record Format:TXT Communication SW:0 Data Type:PG Capacity:2333 File Name:CLAW100 Group Name: Password: Option1: Option2: Option3: Option4: %Data Record \Norm \G-Connect \FuncOn \Y=Type \CoordOn \GridOff \AxesOff \SimulOff \LabelOff \ClrText \ClrGraph \S-Gph1 \DrawOff \S-Gph2 \DrawOff \S-Gph3 \DrawOff \S-WindMan \Cls \File1 \ClrList \ViewWindow 0,128,1,64,0,1 \Plot 30,3 \Plot 23,12 \Orange \Line \Plot 4,12 \Orange \Line \Plot 21,22 \Orange \Line \Plot 13,36 \Orange \Line \Plot 31,26 \Orange \Line \Plot 47,36 \Orange \Line \Plot 40,22 \Orange \Line \Plot 59,12 \Orange \Line \Plot 35,12 \Orange \Line \Plot 30,3 \Orange \Line \Orange \Text 17,19,"HARONA" \Plot 55,21 \Plot 123,21 \Line \Plot 123,45 \Line \Plot 55,45 \Line \Plot 55,21 \Line \Text 29,63,"CHARLES' LAW" \Text 36,57,"WITH THE EA-100" \Plot 0,55 \Plot 128,55 \Line \Plot 0,56 \Plot 128,56 \Line \Text 57,3,"by B.BARONA \and A. Harradine" \Green \Text 45,13,"PUSH [EXE]"\Disp\AxesOn 0\->Z 0\->\theta 1\->C 0\->O 0\->L 1\->K [[0]]\->\Mat A \Seq(0,X,0,10,1)\->\List 5 \ClrGraph \ClrText "CONNECT THE CFX-9850 TO THE EA-100." "PRESS EACH LINK END IN FIRMLY AND TURN THE EA-100 ON." \Locate 16,7,"[EXE]"\Disp\ClrText {1,0}\->\List 6 \Send(\List 6) \ClrText "PLUG TEMPERATURE" "PROBE INTO CHANNEL" "ONE AND PRESSURE" "SENSOR INTO CHANNEL 2" \Locate 16,7,"[EXE]"\Disp\ClrText {1,1,7}\->\List 6 \Send(\List 6) 0\->F "PLEASE NOTE THAT" "UNITS OF PRESSURE" "ARE kPA AND UNITS" "OF TEMPERATURE" "ARE DEGREES CELCIUS." \Locate 16,7,"[EXE]"\Disp{1,2,1}\->\List 6 \Send(\List 6) 221.767\->A 0\->B {4,2,1,0,B,A}\->\List 6 \Send(\List 6) \Lbl 2 \ClrText "ENTER THE TIME BETWEEN SAMPLES." "" ?\->T \ClrText "HOW MANY SAMPLES DO YOU WANT TO COLLECT?" "ENTER 1-255." ?\->R R\->\List 5[1] \ClrText \Seq(0,X,1,R,1)\->\List 1 \Seq(0,X,1,R,1)\->\List 2 \ClrText "SET TEMP-AXIS:" "ENTER TEMP MIN":?\->P \ClrText "ENTER TEMP MAX":?\->Q \ClrText "ENTER TEMP SCALE":?\->S \ClrText "SET PRESSURE AXIS:" "ENTER MIN PRESS":?\->M \ClrText "ENTER MAX PRESS":?\->N \ClrText "ENTER PRESSURE SCALE":?\->O \ClrText "PRESS [EXE] WHEN YOU ARE READY TO BEGIN COLLECTING DATA."\Disp\ClrText \ViewWindow P,Q,S,M,N,O \For 1\->I \To R {3,T,1,0,0}\->\List 6 \Send(\List 6) \Receive(E) E\->\List 1[I] \Receive(E) E\->\List 2[I] \PlotOn \List 1[I],\List 2[I] \Next \Text 1,109,"[EXE]"\Disp\Lbl D \ClrText \ClrGraph \If \Min(\List 2)<0 \Then 1.2\Min(\List 2)\->W \Else .85\Min(\List 2)\->W:\IfEnd \ViewWindow P,Q,S,M,N,O \StoV-Win 1 "Press [EXE] to see a" "clearer graph."\Disp\GridOn \S-Gph1 \DrawOn,\Scatter,\List1,\List2,1,\Square,\Blue \DrawStat \Text 56,100,"TEMP" \Text 2,4,"PRESSURE" \Text 2,109,"[EXE]"\Disp\S-Gph1 \DrawOff \S-Gph2 \DrawOff \S-Gph3 \DrawOff \ClrText "CHOOSE ONE:" "1. REPEAT EXPERIMENT" "2. DO ANALYSIS" ?\->Z \If Z=1:\Then K+1\->K:\Goto2:\IfEnd \Norm \G-Connect \FuncOn \Y=Type \CoordOn \GridOff \AxesOff \SimulOff \LabelOff \ClrText \ClrGraph \S-Gph1 \DrawOff \S-Gph2 \DrawOff \S-Gph3 \DrawOff \S-WindMan \ClrText \Text 1,1,"\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster" \Orange \Text 7,1," HARONA SOFTWARE " \Text 13,1,"-----------------------------" \Text 19,1," " \Text 25,1," THANKYOU FOR USING " \Text 31,1," OUR SOFTWARE. " \Orange \Text 37,1," DO NOT PUSH [EXE] " \Text 43,1," " \Text 49,1,"\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster\aster" \Orange \Text 58,42,"PUSH [MENU]"\Disp\Cls \Orange \Text 8,1," \aster\aster\asterWARNING!\aster\aster\aster " \Orange \Text 25,1," Please press " \Orange \Text 31,1," [MENU] NOT [EXE] " \Orange \Text 37,1," \or your data will be lost. " \Orange \Text 48,1," This is your last warning! " \Stop %End